Abbott Epic Mitral Bioprosthetic Heart Valve – E100 Series
The Abbott Epic™ Mitral Bioprosthetic Heart Valve (item #E100 series) is a stented porcine tissue valve designed for mitral valve replacement in patients with diseased, damaged, or malfunctioning native or prosthetic mitral valves. The valve features a flexible polymer stent, low ventricular protrusion, and a flexible sewing cuff to facilitate secure implantation and minimize paravalvular leak. Its design incorporates individually selected porcine leaflets to ensure optimal coaptation and hemodynamic performance.
Product Code: E100 series
- Design: Stented Porcine Tissue Valve
- Material: Porcine Tissue Leaflets, Polymer Stent, Polyester Sewing Cuff
- Application: Mitral Valve Replacement
- Implantable
- Single-Use, Disposable
- Sterile
Additional Details
- Brand: Abbott (formerly St. Jude Medical)
- Category: Structural Heart / Surgical Heart Valves
- Type: Bioprosthetic Mitral Heart Valve
- FDA Product Code: LWR
- FDA Product Code Name: Heart-valve, non-allograft tissue
- GMDN Term Name: Mitral heart valve bioprosthesis
- GMDN Term Definition: A xenograft (e.g., porcine or bovine heart valve) intended to be implanted in a patient during open heart surgery to repair or replace a dysfunctional mitral heart valve. It is processed to render the tissue in the valve non-viable; it may be tissue only, or tissue attached to a metal or synthetic polymer framework. The device is typically used to treat acquired or congenital valvular disease.
AccessGUDID Info
- FDA Product Code: LWR
- FDA Product Code Name: heart-valve, non-allograft tissue
- GMDN Term Code: 60244
- GMDN Term Name: Mitral open-surgery heart valve bioprosthesis
- GMDN Term Description: A xenograft (e.g., porcine or bovine heart valve) intended to be implanted in a patient during open heart surgery to repair or replace a dysfunctional mitral heart valve. It is processed to render the tissue in the valve non-viable; it may be tissue only, or tissue attached to a metal or synthetic polymer framework. The device is typically used to treat acquired or congenital valvular disease.
Manufacturer
Abbott’s surgical innovations deliver advanced solutions that enhance precision, safety, and outcomes in the operating room. Building on the legacy of St. Jude Medical, Abbott offers a diverse portfolio of cutting-edge technologies, including structural heart devices like MitraClip™ for mitral valve repair and Amplatzer™ occluders for congenital heart defect closure. Their ProGlide™ vascular closure system and TactiCath™ ablation catheters further demonstrate Abbott’s commitment to empowering surgeons with reliable tools for minimally invasive procedures. By combining innovation with trusted expertise, Abbott continues to shape the future of surgical care. Browse Synergy Surgical's selection of Abbott surgical products, including Balloons, Stents, Vascular Closures and more.