CFF03: Applied Medical Kii Fios First Entry, Advanced Fixation 5mm x 100mm

Sign in to add this product to your favorites!
| Price: | $75.00 per box of 6 |
|---|---|
| Quantity: | |
| In Stock: | 1 box of 6 |
| Status: | expired |
| Express: | Need it tomorrow? Order in next 5 hours 41 minutes and choose overnight shipping at checkout. |
Related Items
CTF04 - Size: 5.00mm $13.00 EACH Applied Medical Kii Fios First Entry, Z-Thread 5mm x 100mm, Handled Expired Units in stock: 2 | Order Qty |
CTS02 - Size: 5.00mm $2.85 EACH Applied Medical Kii Sleeve, Z-Thread 5mm x 100mm Expired Units in stock: 1 | Order Qty |
C0Q20 - Size: 5.00mm $15.00 EACH Applied Medical Kii Balloon Blunt-Tip Trocar Access System 5mm x 100mm Expired Units in stock: 1 | Order Qty |
IAS5-100LP - Size: 5.00mm $5.00 EACH ConMed AirSeal 5mm Access Port with Bladeless Optical Tip, 100mm Expired Units in stock: 4 | Order Qty |
CTB03 - Size: 5.00mm $4.25 EACH Applied Medical Kii Shielded Bladed Trocar, Z-Thread 5mm x 100mm Expired Units in stock: 1 | Order Qty |
CFS02 - Size: 5.00mm $5.00 EACH Applied Medical Kii Sleeve, Advanced Fixation 5mm x 100mm Expired Units in stock: 1 | Order Qty |
CFB03 - Size: 5.00mm $59.00 per box of 6 Applied Medical Kii Shielded Bladed Trocar, Advanced Fixation 5mm x 100mm Expired Units in stock: 1 box of 6 | Order Qty |
Additional Details
Applied Medical Kii Fios First Entry
Establishing safe pneumoperitoneum has always been the most critical part of laparoscopy. In response to this key clinical need, Applied Medical has developed Kii Fios first entry, the next revolution in laparoscopic access. Upon immediate penetration of the peritoneum under direct visualization, Kii Fios first entry creates a space for the tip of the obturator.
In seconds, pneumoperitoneum is established at up to three times the rate of alternative methods with only a 3mm intrusion into the peritoneal cavity. Kii Fios first entry has the potential to significantly reduce the risk of injuries while establishing secure, controlled pneumoperitoneum in laparoscopic procedures.
By combining the benefits of the veress needle and optical non-bladed trocar, Kii Fios First Entry can save valuable OR time and reduce cost by eliminating the need for blind veress needle entry prior to trocar placement. Kii Fios first entry is the ideal first entry port for any laparoscopic procedure.
Sterilization
- Device Packaged as Sterile: Yes
- Requires Sterilization Prior to Use: No
- Single-Use
- Disposable
Additional Details
- Company Name: Applied Medical Resources Corporation
- FDA Product Code: GCJ
- FDA Product Code Name: Laparoscope, General & Plastic Surgery
- GMDN Term Code: 42412
- GMDN Term Name: Laparoscopic access cannula, single-use
- GMDN Term Definition: A single-lumen surgical device intended to be percutaneously inserted through the abdominal wall to create an access port for a laparoscope/laparoscopic instrument during laparoscopy. The cannula is provided with a shut-off valve for gas/fluid supply, and other sealing devices (e.g., dedicated seals/rings, caps, valves), to prevent insufflation gas leakage whilst allowing entry of instruments; it may additionally be intended for thoracoscopy whereby the valve may not be required. It may include a sharp or blunt trocar blade to assist introduction and/or puncture the abdominal wall; if the trocar is included it may be referred to as a trocar or trocar assembly. This is a single-use device.
AccessGUDID Info
- FDA Product Code: GCJ
- FDA Product Code Name: Laparoscope, General & Plastic Surgery
- GMDN Term Code: 42412
- GMDN Term Name: Laparoscopic access cannula, single-use
- GMDN Term Description: A single-lumen surgical device intended to be percutaneously inserted through the abdominal wall to create an access port for a laparoscope/laparoscopic instrument during laparoscopy. The cannula is provided with a shut-off valve for gas/fluid supply, and other sealing devices (e.g., dedicated seals/rings, caps, valves), to prevent insufflation gas leakage whilst allowing entry of instruments; it may additionally be intended for thoracoscopy whereby the valve may not be required. It may include a sharp or blunt trocar blade to assist introduction and/or puncture the abdominal wall; if the trocar is included it may be referred to as a trocar or trocar assembly. This is a single-use device.
Manufacturer
Applied Medical is a global leader in minimally invasive surgical technologies, dedicated to advancing patient outcomes through innovation and sustainability. Known for its advanced laparoscopic solutions, Applied Medical offers a wide range of products, including the GelPOINT® platform for single-incision surgeries and the Alexis® wound protector-retractor for enhanced exposure and protection. With a strong focus on reducing healthcare costs and improving procedural efficiency, Applied Medical empowers surgeons with reliable, high-performance devices. Committed to clinical excellence and environmental responsibility, Applied Medical continues to set new standards in surgical care.
IN-DATE