43-102: Inari InThrill Thrombectomy Catheter

Sign in to add this product to your favorites!
| Price: | $1,999.00 $999.50 per box of 1 |
|---|---|
| Quantity: | |
| In Stock: | 18 box of 1 |
| Status: | expired |
| Express: | Need it tomorrow? Order in next 12 hours 42 minutes and choose overnight shipping at checkout. |
Related Items
53-101 - Size: 8.0F $1,899.00 $1,424.25 per box of 1 Inari InThrill Thrombectomy Sheath 8F x 6cm Expired Units in stock: 27 box of 1 | Order Qty |
WV8803A - Size: 8.0F $1,299.00 per kit Abbott JETi Thrombectomy Catheter Kit w/Catheter, Pump Set & Suction Tubing 8F x 100cm Expired Units in stock: 10 kits | Order Qty |
WV088F - Size: 8.0F $1,199.00 per box of 1 Abbott JETi Thrombectomy Catheter 8F Expired Units in stock: 1 box of 1 | Order Qty |
Additional Details
Inari InThrill Thrombectomy Catheter
8F system designed to maximize thrombus removal in AV Fistulae and Grafts. The InThrill thrombectomy system is an over-the-wire system optimized for the removal of thrombus in smaller venous vessels (4–10 mm) within the peripheral vasculature. For use with Inari InThrill Thrombectomy Sheath REF # 53-101.
Product Code: 43-102
- Inari InThrill Thrombectomy Catheter
Additional Details
- Company Name: Inari Medical / Stryker
- FDA Product Code: QEW
- FDA Product Code Name: Peripheral Mechanical Thrombectomy With Aspiration
- FDA Product Code: KRA
- FDA Product Code Name: Catheter, Continuous Flush
- GMDN Term Code: 61779
- GMDN Term Name: Thrombectomy wire-net
- GMDN Term Definition: A device intended to be percutaneously introduced into the vasculature (coronary, peripheral and/or intracranial) through an appropriate intravascular catheter for the removal of clotted blood (i.e., a thrombus or thromboembolus) or other formed elements causing vascular obstruction; revascularization may also be achieved through thrombus reorientation. Also referred to as a stent retriever or clot retrieval catheter, it consists of an expanding, stent-like wire net connected to a pusher wire primarily intended to grip and remove the emboli/thrombi; it might include a guide-catheter dedicated to introduction of the wire-net. This is a single-use device.
AccessGUDID Info
- FDA Product Code: QEW
- FDA Product Code Name: Peripheral Mechanical Thrombectomy With Aspiration
- FDA Product Code: KRA
- FDA Product Code Name: Catheter, Continuous Flush
- GMDN Term Code: 61779
- GMDN Term Name: Thrombectomy wire-net
- GMDN Term Description: A device intended to be percutaneously introduced into the vasculature (coronary, peripheral and/or intracranial) through an appropriate intravascular catheter for the removal of clotted blood (i.e., a thrombus or thromboembolus) or other formed elements causing vascular obstruction; revascularization may also be achieved through thrombus reorientation. Also referred to as a stent retriever or clot retrieval catheter, it consists of an expanding, stent-like wire net connected to a pusher wire primarily intended to grip and remove the emboli/thrombi; it might include a guide-catheter dedicated to introduction of the wire-net. This is a single-use device.
Manufacturer
Inari Medical specializes in innovative, catheter-based solutions for venous thromboembolism (VTE). Their flagship products include the ClotTriever system for mechanical thrombectomy in deep vein thrombosis (DVT) and the FlowTriever system, the first FDA-cleared device for pulmonary embolism (PE) treatment without the need for thrombolytics. These systems are designed to remove large clots in a single session, reducing the need for ICU stays, thrombolytic drugs, and prolonged hospitalizations. With a focus on transforming the treatment paradigm for venous disease, Inari is redefining outcomes for patients suffering from life-threatening clot-related conditions.
IN-DATE