PTS253: Braun PTS Sizing Balloon Catheter 25mm x 30mm, 80cm

Sign in to add this product to your favorites!
| Price: | $99.00 per box of 1 |
|---|---|
| Quantity: | |
| In Stock: | 2 box of 1 |
| Status: | expired |
Related Items
PTS405 - Size: 40.00mm $99.00 per box of 1 Braun PTS Sizing Balloon Catheter 40mm x 50mm, 80cm Expired Units in stock: 2 box of 1 | Order Qty |
PVN410 - Size: 25.00mm $349.00 per box of 1 Braun NuCLEUS-X Balloon Aortic & Pulmonary Valvuloplasty Catheter 25mm x 50mm x 110cm Expired Units in stock: 1 box of 1 | Order Qty |
PVN411 - Size: 25.00mm $349.00 per box of 1 Braun NuCLEUS-X Balloon Aortic & Pulmonary Valvuloplasty Catheter 25mm x 60mm x 110cm Expired Units in stock: 1 box of 1 | Order Qty |
417-2540S - Size: 25.00mm $39.00 per box of 1 Cordis Maxi LD Dilatation Catheter 25mm x 40mm, 80cm Expired Units in stock: 5 box of 1 | Order Qty |
417-2540L - Size: 25.00mm $39.00 per box of 1 Cordis Maxi LD Dilatation Catheter 25mm x 40mm, 110cm Expired Units in stock: 3 box of 1 | Order Qty |
611769 - Size: 25.00mm $149.00 per box of 1 Braun Z-Med II Balloon Dilatation Catheter 25mm x 40mm, 100cm Expired Units in stock: 1 box of 1 | Order Qty |
611805 - Size: 25.00mm $149.00 per box of 1 Braun Z-Med II Balloon Dilatation Catheter 25mm x 30mm, 120cm Expired Units in stock: 2 box of 1 | Order Qty |
Additional Details
B. Braun PTS Sizing Balloon Catheter
- Designed for use in patients with cardiovascular defects where accurate measurement of the defect is important to select the appropriately sized occluder device
- Super-thin for a low deflated profile that maintains tip flexibility
- Short tapers at the distal and proximal ends for enhanced transition across the stenosis and post dilatation ease of withdrawl into the introducer
AccessGUDID Info
- FDA Product Code: MJN
- FDA Product Code Name: Catheter, intravascular occluding, temporary
- GMDN Term Code: 42417
- GMDN Term Name: Cardiac sizing catheter
- GMDN Term Description: A sterile flexible tube with an inflatable balloon at the distal end designed for use in a patient with a cardiovascular defect wherein accurate measurement of the defect is important to select the appropriately sized occlusion device. It is typically designed to pass over a guidewire and it will have radiopaque marker bands along it distal end to assist in placement using fluoroscopy. It is made of plastic materials and metal [e, g, platinum (Pt) for the bands] and is available in a variety of designs and sizes. This is a single-use device.
Manufacturer
B. Braun Interventional Systems Inc. is part of the B. Braun Group of Companies and specializes in medical devices used in interventional radiology, vascular procedures, and related minimally invasive applications.
The company’s portfolio includes vena cava filter systems, vascular access and introducer products, drainage devices, and other interventional technologies designed to support image-guided procedures and vascular treatment. Products such as the VenaTech™ vena cava filter systems are used for prevention of pulmonary embolism in appropriately selected patients.
B. Braun Interventional Systems combines device design, clinical application expertise, and the broader manufacturing capabilities of the B. Braun organization to support interventional and vascular procedures across hospital and outpatient settings.