MUS0130069X6: Medtronic Mo.Ma Ultra Proximal Cerebral Protection Device 9F

Sign in to add this product to your favorites!
| Price: | $364.00 $182.00 per box of 1 |
|---|---|
| Quantity: | |
| In Stock: | 4 box of 1 |
| Status: | expired |
| Express: | Need it tomorrow? Order in next 5 hours 34 minutes and choose overnight shipping at checkout. |
Additional Details
Medtronic MUS0130069X6 ev3 Mo.Ma Ultra Proximal Cerebral Protection Device
The Medtronic Mo.Ma Ultra Proximal Cerebral Protection Device is a sterile, single-use embolic protection system designed for angioplasty and stenting procedures involving lesions of the internal carotid artery or carotid bifurcation. Its double-balloon design provides proximal flow control before the lesion is crossed, helping contain and remove thrombus and other embolic debris through aspiration during carotid interventions.
Product Code: MUS0130069X6
- Brand: Mo.Ma Ultra
- Device Type: Proximal Cerebral Embolic Protection Device
- System Design: Double-Balloon
- Minimum Sheath Size: 9F
- Working Channel Inner Diameter: 0.083in (2.12mm)
- Recommended Guidewire: 0.035in (0.89mm)
- Balloon Marker Distance: 6cm
- Proximal Balloon Occlusion Range: 5mm to 13mm
- Distal Balloon Occlusion Range: 3mm to 6mm
- Balloon Material: Compliant Elastomeric Rubber
- Application: Carotid Angioplasty and Stenting
- Single-Use
Sterilization
- Device Packaged as Sterile: Yes
- Requires Sterilization Prior to Use: No
AccessGUDID Info
- FDA Product Code: NTE
- FDA Product Code Name: Temporary Carotid Catheter for Embolic Capture
- GMDN Term Code: 58112
- GMDN Term Name: Carotid artery embolic protection system
- GMDN Term Description: An assembly of devices intended to provide cerebrovascular embolic protection during carotid artery angioplasty and stenting procedures. It is available in various configurations and typically includes a sheath/catheter(s), intravascular balloon(s), guidewire, and extracorporeal valves/filters. The assembly is introduced into an artery percutaneously and used to produce blockage of blood through balloon inflation, typically at the carotid bifurcation and internal carotid artery to prevent distal embolization by particulate debris/thrombus and allow removal of debris/thrombus by blood filtration or aspiration. This is a single-use device.
Manufacturer
Medtronic Cardiovascular Therapies offers a broad range of solutions for treating peripheral artery disease, aortic aneurysms, deep vein thrombosis, and other vascular conditions. Key technologies include the Endurant II and Endurant IIs stent graft systems for abdominal aortic aneurysms, the IN.PACT Admiral drug-coated balloon for femoropopliteal disease, and the Abre venous self-expanding stent system for iliofemoral venous outflow obstruction. With a commitment to advancing minimally invasive therapies, Medtronic’s vascular innovations help restore blood flow, reduce procedural risk, and improve quality of life for patients with complex vascular disease.
There is no valid manufacturer warranty on the products that Synergy Surgical sells. Any services provided by the original manufacturer of the products we sell are not available. However, eSutures offers a 100% money back guarantee (less shipping) on every item we sell within 30 days of purchase. For details, please see our Return Policy.
IN-DATE