LSP202V: Abbott Aveir RV Right Ventricular Leadless Cardiac Pacemaker

Sign in to add this product to your favorites!
| Price: | $8,999.00 per box of 1 |
|---|---|
| Quantity: | |
| In Stock: | 1 box of 1 |
| Expiration: | 08-2027 |
| Express: | Need it tomorrow? Order in next 13 hours 23 minutes and choose overnight shipping at checkout. |
Related Items
EX1150 $599.00 per box of 1 Abbott Merlin Home Transmitter Exp: 01-2050 Units in stock: 3 box of 1 | Order Qty |
MDT407658-SD $349.99 per box of 1 Medtronic CapSureFix Novus MRI SureScan Transvenous Lead, 58cm Exp: 02-2027 Units in stock: 2 box of 1 | Order Qty |
383069 $549.00 per box of 1 Medtronic SelectSecure MRI SureScan Lead 69cm Exp: 05-2027 Units in stock: 2 box of 1 | Order Qty |
MI2355A $599.00 per box of 1 Medtronic Micra Introducer w/Hydrophilic Coating Exp: 02-2027 (or later) Units in stock: 2 box of 1 | Order Qty |
2088TC-58 $425.00 per box of 1 Abbott SJM Tendril STS Pacing Lead, 58cm Exp: 04-2027 Units in stock: 2 box of 1 | Order Qty |
MI2355A-SD $299.99 per box of 1 Medtronic Micra Introducer w/Hydrophilic Coating Exp: 12-2026 Units in stock: 3 box of 1 | Order Qty |
Additional Details
Abbott LSP202V AVEIR VR Right Ventricular Leadless Pacemaker
Abbott LSP202V AVEIR VR is an implantable right ventricular leadless pacemaker designed to provide rate-responsive bradycardia pacing without a transvenous pacing lead or surgically created pulse-generator pocket. The 38.0 mm x 6.5 mm device uses a distal non-retractable helix for active fixation in the right ventricle and can function as the ventricular component of the AVEIR DR dual-chamber leadless pacing system.
Product Code: LSP202V
- Manufacturer: Abbott
- Product Name: AVEIR VR Leadless Pacemaker
- Brand / Product Family: AVEIR
- Device Type: Right ventricular leadless pacemaker
- Implant Location: Right ventricle
- Length: 38.0 mm (1.50 in)
- Diameter: 6.5 mm (0.26 in)
- Mass: 2.4 g
- Volume: 1.1 cc
- Fixation Mechanism: Distal non-retractable helix
- Distal Electrode Configuration: Domed
- Clinical Application: Rate-responsive bradycardia pacing
- Procedure Type: Transcatheter leadless pacemaker implantation
- Specialty: Cardiology
- Anatomical Application: Right ventricle
- System Compatibility: Can function with a compatible AVEIR atrial leadless pacemaker as part of the AVEIR DR system
- Implantable: Yes
- MR Status: MR Conditional
Features
- Leadless design eliminates the need for a transvenous pacing lead and subcutaneous pulse-generator pocket
- Active helix fixation secures the device directly within the myocardium
- Designed for retrieval when clinically appropriate
- Supports implant-to-implant communication when paired with a compatible AVEIR atrial leadless pacemaker for dual-chamber pacing
Sterilization
- Device Packaged as Sterile: Yes
- Requires Sterilization Prior to Use: No
AccessGUDID Info
- FDA Product Code: PNJ
- FDA Product Code Name: Leadless pacemaker
- GMDN Term Code: 60789
- GMDN Term Name: Intracardiac pacemaker
- GMDN Term Description: A battery-powered, hermetically-sealed pulse generator impregnated with a steroid (e.g., dexamethasone) intended to be implanted with a catheter, via transvenous access, into the right ventricle (i.e., single-chamber pacing) of an arrhythmic heart to generate/conduct electrical impulses to improve cardiac output. It contains sensors to detect changes in the body (e.g., motion, breathing frequency) and to adjust the pacing rate accordingly (rate-responsive). Wireless telemetry with external devices enables programming adjustments and may allow on-going heart monitoring; it does not provide defibrillation therapy. Disposable devices associated with implantation may be included.
Manufacturer
Abbott’s surgical innovations deliver advanced solutions that enhance precision, safety, and outcomes in the operating room. Building on the legacy of St. Jude Medical, Abbott offers a diverse portfolio of cutting-edge technologies, including structural heart devices like MitraClip™ for mitral valve repair and Amplatzer™ occluders for congenital heart defect closure. Their ProGlide™ vascular closure system and TactiCath™ ablation catheters further demonstrate Abbott’s commitment to empowering surgeons with reliable tools for minimally invasive procedures. By combining innovation with trusted expertise, Abbott continues to shape the future of surgical care. Browse Synergy Surgical's selection of Abbott surgical products, including Balloons, Stents, Vascular Closures and more.
IN-DATE