ANPP7199: Rapid Medical Comaneci 17 Embolization Assist Device, Adjustable Remodeling Mesh

Sign in to add this product to your favorites!
| Price: | $4,279.00 $2,139.50 per box of 1 |
|---|---|
| Quantity: | |
| In Stock: | 1 box of 1 |
| Expiration: | 11-2027 |
Related Items
TRPP7166 $6,799.00 $3,399.50 per box of 1 Rapid Medical TigerTriever 17 Revascularization Device Exp: 11-2026 (or later) Units in stock: 10 box of 1 | Order Qty |
TRPP7155 $6,799.00 $3,399.50 per box of 1 Rapid Medical TigerTriever Revascularization Device Exp: 02-2027 (or later) Units in stock: 11 box of 1 | Order Qty |
TRPP7155-SD $4,799.99 $2,399.99 per box of 1 Rapid Medical TigerTriever Revascularization Device (EXPIRES 7/31/26) Exp: 07-2026 Units in stock: 7 box of 1 | Order Qty |
UZAS4021 $7,499.00 per box of 1 Stryker Neuroform Atlas Stent System 4.0mm x 21mm Exp: 09-2027 (or later) Units in stock: 2 box of 1 | Order Qty |
UZAS4024 $7,499.00 per box of 1 Stryker Neuroform Atlas Stent System 4.0mm x 24mm Exp: 10-2027 (or later) Units in stock: 2 box of 1 | Order Qty |
UZAS3015 $7,499.00 per box of 1 Stryker Neuroform Atlas Stent System 3.0mm x 15mm Exp: 05-2028 (or later) Units in stock: 3 box of 1 | Order Qty |
TG5411530 $1,989.00 EACH Stryker Target Tetra Detachable Embolization Coil 1.5mm x 3cm (No Box) Exp: 06-2027 Units in stock: 1 | Order Qty |
UZAS4521 $7,499.00 per box of 1 Stryker Neuroform Atlas Stent System 4.5mm x 21mm Exp: 12-2026 (or later) Units in stock: 3 box of 1 | Order Qty |
UZAS4530 $7,499.00 per box of 1 Stryker Neuroform Atlas Stent System 4.5mm x 30mm Exp: 07-2029 Units in stock: 1 box of 1 | Order Qty |
UZAS3024 $7,499.00 per box of 1 Stryker Neuroform Atlas Stent System 3.0mm x 24mm Exp: 07-2029 Units in stock: 1 box of 1 | Order Qty |
UZAS3021 $7,499.00 per box of 1 Stryker Neuroform Atlas Stent System 3.0mm x 21mm Exp: 06-2028 (or later) Units in stock: 4 box of 1 | Order Qty |
Additional Details
Rapid Medical Comaneci 17 Embolization Assist Device, Adjustable Remodeling Mesh
The Comaneci is intended for use in the neurovasculature to assist in the coil embolization of wide-necked intracranial aneurysms under fluoroscopic guidance. The Comaneci is comprised of a collapsible, fully retrievable, fine wire construction mounted on a wire shaft that expands to comply with the vessel diameter. It is delivered through a neurovascular microcatheter. The Comaneci is provided with a 3.5 French (F) peelable loading sheath.
Product Code: ANPP7199
- Net Length: 22mm
- Compatibility: 0.017” ID microcatheter
- Diameter: 0.5mm - 3mm
Sterilization
- Device Packaged as Sterile: Yes
- Requires Sterilization Prior to Use: No
- Single-Use
- Disposable
Additional Details
- Company Name: Rapid Medical, Ltd.
- FDA Product Code: PUU
- FDA Product Code Name: Temporary Coil Embolization Assist Device
- GMDN Term Code: 46352
- GMDN Term Name: Bare-metal intracranial vascular stent
- GMDN Term Definition: A non-bioabsorbable tubular device typically intended to be implanted into the base or parent artery of an intracranial aneurysm (e.g., wide-neck aneurysm situated at the base of a bifurcation) to facilitate the delivery of embolics to fill the aneurysm, facilitate clotting within the aneurysm by slowing blood flow into it, and/or to provide support for a neurovascular embolization coil placed inside the aneurysm. It is made of uncoated metal [e.g., nickel-titanium alloy (Nitinol)] and self-expands after it is delivered to the site of implantation and released (e.g., from a dedicated delivery instrument). Disposable devices associated with implantation may be included.
AccessGUDID Info
- FDA Product Code: PUU
- FDA Product Code Name: Temporary Coil Embolization Assist Device
- GMDN Term Code: 46352
- GMDN Term Name: Bare-metal intracranial vascular stent
- GMDN Term Description: A non-bioabsorbable tubular device typically intended to be implanted into the base or parent artery of an intracranial aneurysm (e.g., wide-neck aneurysm situated at the base of a bifurcation) to facilitate the delivery of embolics to fill the aneurysm, facilitate clotting within the aneurysm by slowing blood flow into it, and/or to provide support for a neurovascular embolization coil placed inside the aneurysm. It is made of uncoated metal [e.g., nickel-titanium alloy (Nitinol)] and self-expands after it is delivered to the site of implantation and released (e.g., from a dedicated delivery instrument). Disposable devices associated with implantation may be included.
Manufacturer
Rapid Medical is a medical device company specializing in innovative neurovascular solutions. They focus on minimally invasive devices designed for acute ischemic stroke treatment, such as their TigerTriever thrombectomy device. The company is dedicated to providing cutting-edge solutions for the endovascular treatment of vascular diseases, improving patient outcomes in neurointerventional procedures.
IN-DATE