40-102: Inari ClotTriever Catheter 16mm x 105cm

Sign in to add this product to your favorites!
| Price: | $7,999.00 per box of 1 |
|---|---|
| In Stock: | 0 box of 1 |
| Expiration: | In-Date |
We currently do not have this item in stock, but we can email you as soon as it is available.
Related Items
41-102 - Size: 16.00mm $7,999.00 per box of 1 Inari ClotTriever XL Catheter 16mm x 115cm, Variable In-Date Out of Stock |
51-101 - Size: 16.0F $2,245.00 EACH Inari ClotTriever Sheath 16F (No Box) In-Date Out of Stock |
41-102-SD - Size: 16.00mm $6,499.99 per box of 1 Inari ClotTriever XL Catheter 16mm x 115cm, Variable In-Date Out of Stock |
40-102 - Size: 16.00mm $7,989.00 EACH Inari ClotTriever Catheter 16mm x 105cm (No Box) Exp: 08-2027 Units in stock: 2 | Order Qty |
50-101 - Size: 13.0F $2,250.00 per box of 1 Inari ClotTriever Sheath 13F In-Date Out of Stock |
51-101 - Size: 16.0F $2,250.00 per box of 1 Inari ClotTriever Sheath 16F In-Date Out of Stock |
Additional Details
Stryker Inari 40-102 ClotTriever Catheter 16 mm
Stryker Inari 40-102 is a ClotTriever Catheter designed for mechanical thrombectomy and non-surgical removal of thrombi and emboli from the peripheral vasculature. The catheter uses a distal coring element and expandable collection bag to engage and capture thrombotic material during venous thrombectomy procedures, including treatment of deep vein thrombosis.
Product Code: 40-102
- Manufacturer: Inari Medical, a Stryker company
- Product Name: ClotTriever Catheter
- Product Family: ClotTriever
- Device Type: Mechanical thrombectomy catheter
- Coring Element Diameter: 16 mm
- Guidewire Compatibility: 0.035 in
- Configuration: Coaxial catheter with distal coring element and collection bag
- Application: Non-surgical removal of thrombi and emboli from blood vessels
- Procedure Type: Percutaneous mechanical thrombectomy
- Specialty: Interventional Radiology, Vascular Surgery, Interventional Cardiology
- Anatomical Application: Peripheral vasculature
- Clinical Application: Deep vein thrombosis thrombectomy
Features
- Expandable coring element is designed to engage thrombus within the vessel
- Collection bag captures retrieved thrombotic material during catheter withdrawal
- Radiopaque distal tip and marker bands support fluoroscopic visualization
- Proximal handle controls deployment of the collection bag and coring element
- Supports injection, infusion, and aspiration of compatible fluids through the catheter system
Sterilization
- Device Packaged as Sterile: Yes
- Requires Sterilization Prior to Use: No
- Single-Use, Disposable
Manufacturer
Inari Medical specializes in innovative, catheter-based solutions for venous thromboembolism (VTE). Their flagship products include the ClotTriever system for mechanical thrombectomy in deep vein thrombosis (DVT) and the FlowTriever system, the first FDA-cleared device for pulmonary embolism (PE) treatment without the need for thrombolytics. These systems are designed to remove large clots in a single session, reducing the need for ICU stays, thrombolytic drugs, and prolonged hospitalizations. With a focus on transforming the treatment paradigm for venous disease, Inari is redefining outcomes for patients suffering from life-threatening clot-related conditions.
IN-DATE