9-VSD-MUSC-018: Abbott SJM Amplatzer Muscular VSD Occluder 18mm x 26mm

Sign in to add this product to your favorites!
| Price: | $7,999.00 per box of 1 |
|---|---|
| Quantity: | |
| In Stock: | 4 box of 1 |
| Expiration: | 01-2030 |
| Express: | Need it tomorrow? Order in next 1 hours 29 minutes and choose overnight shipping at checkout. |
Related Items
9-VSD-MUSC-016 - Size: 16.00mm $7,999.00 per box of 1 Abbott SJM Amplatzer Muscular VSD Occluder 16mm x 24mm Exp: 12-2029 Units in stock: 4 box of 1 | Order Qty |
9-VSD-MUSC-012 - Size: 12.00mm $7,999.00 per box of 1 Abbott SJM Amplatzer Muscular VSD Occluder 12mm x 20mm Exp: 02-2030 Units in stock: 4 box of 1 | Order Qty |
9-ASD-MF-018 - Size: 18.00mm $3,999.00 per box of 1 SJM Amplatzer Multi-Fenestrated Septal Occluder, Cribriform 18mm Exp: 09-2029 Units in stock: 1 box of 1 | Order Qty |
9-ASD-018 - Size: 18.00mm $3,999.00 per box of 1 SJM Amplatzer Septal Occluder 18mm Exp: 06-2027 Units in stock: 1 box of 1 | Order Qty |
Additional Details
Abbott SJM Amplatzer Muscular VSD Occluder
Ventricular septal defects (VSDs) are the most commonly found congenital heart defect.1 The AMPLATZER™ Muscular VSD Occluder was specially designed to close complex muscular VSDs, including in patients considered to be high risk for standard surgical repair.
Engineered for complete closure
- Device waist centers and fills the defect.
- Polyester material promotes occlusion and tissue in-growth.
- 7 mm waist length accommodates the thickness of the muscular ventricular septal wall.
Procedural flexibility
- Symmetrical design allows a femoral or arterial delivery approach.
- Designed to be recaptured and redeployed for precise placement.
Sterilization
- Device Packaged as Sterile: Yes
- Requires Sterilization Prior to Use: No
- Single-Use
- Disposable
Additional Details
- Company Name: AGA Medical Corporation
- FDA Product Code: MLV
- FDA Product Code Name: Transcatheter septal occluder
- GMDN Term Code: 45418
- GMDN Term Name: Cardiac defect occluder
- GMDN Term Definition: An implantable disk-like device intended to be used for the minimally-invasive closure of cardiac defects and deployed using a dedicated delivery catheter/sheath. It is made of wire mesh [e.g., nickel-titanium alloy (Nitinol)], and possibly additional materials (e.g., polyester), and is typically self-expandable. The device is used to treat cardiac disorders that may include (but not limited to) atrial septal defect (ASD), ventricular septal defect (VSD), patent foramen ovale (PFO), or patent ductus arteriosus (PDA). Disposable devices dedicated to implantation may be included with the implant.
AccessGUDID Info
- FDA Product Code: MLV
- FDA Product Code Name: Transcatheter septal occluder
- GMDN Term Code: 45418
- GMDN Term Name: Cardiac defect occluder
- GMDN Term Description: An implantable disk-like device intended to be used for the minimally-invasive closure of cardiac defects and deployed using a dedicated delivery catheter/sheath. It is made of wire mesh [e.g., nickel-titanium alloy (Nitinol)], and possibly additional materials (e.g., polyester), and is typically self-expandable. The device is used to treat cardiac disorders that may include (but not limited to) atrial septal defect (ASD), ventricular septal defect (VSD), patent foramen ovale (PFO), or patent ductus arteriosus (PDA). Disposable devices dedicated to implantation may be included with the implant.
Manufacturer
Abbott St. Jude Medical has long been a leader in vascular care, through its stents and related products. And, in recent years, the company has built a strong position in mitral valve repair with its MitraClip device. The agreement to acquire St. Jude Medical broadens Abbott's presence in virtually every aspect of cardiovascular care, and will make Abbott one of the world leaders in the broad medical device market.
IN-DATE