0234512: Bard True Dilatation Balloon Valvuloplasty Catheter 23mm x 45mm, 110cm

Sign in to add this product to your favorites!
| Price: | $799.00 per box of 1 |
|---|---|
| Quantity: | |
| In Stock: | 9 box of 1 |
| Expiration: | 12-2028 |
| Express: | Need it tomorrow? Order in next 10 hours 38 minutes and choose overnight shipping at checkout. |
Related Items
0234512 - Size: 23.00mm $795.00 EACH Bard True Dilatation Balloon Valvuloplasty Catheter 23mm x 45mm, 110cm (No Box) Exp: 01-2029 Units in stock: 1 | Order Qty |
0224512-SD - Size: 22.00mm $644.99 EACH Bard True Dilatation Balloon Valvuloplasty Catheter 22mm x 45mm, 110cm (No Box) Exp: 08-2026 Units in stock: 1 | Order Qty |
Additional Details
BD Becton-Dickinson Bard True Dilatation® Balloon Valvuloplasty Catheters
The Bard True Dilatation Balloon Valvuloplasty Catheter is engineered for controlled dilatation of cardiac valves. Its non-compliant balloon technology provides accurate sizing, predictable expansion, and consistent performance across a wide range of anatomies. Designed for reliable deliverability and stability, it supports precise and effective valvuloplasty procedures.
Product Code: 0234512
- Diameter: 23mm
- Length: 4.5cm
- Catheter Length: 110cm
- Sheath Size: 12F
Features
- Truly Precise – Accurate, reliable sizing
- Truly Fast – Designed to minimize rapid pacing times
- Truly Rupture Resistant – Engineered to avoid catastrophic failure
Sterilization
- Device Packaged as Sterile: Yes
- Requires Sterilization Prior to Use: No
- Single-Use
- Disposable
Additional Details
- Company Name: Bard Peripheral Vascular, Inc.
- FDA Product Code: OZT
- FDA Product Code Name: Balloon aortic valvuloplasty
- GMDN Term Code: 17453
- GMDN Term Name: Cardiac valvuloplasty catheter
- GMDN Term Definition: A sterile flexible tube with an inflatable balloon designed to perform plastic or restorative surgery on a cardiac valve, i.e., for the dilatation of atrioventricular, aortic, and pulmonary trunk valves. It is typically used for the percutaneous dilatation of commissural fusion in stenotic mitral valves and for annular, cuspal, and calcific nodular fractures, to improve cuspal mobility in adult calcific aortic stenosis, and for leaflet tearing in pulmonic valve stenosis. It may also be used for percutaneous balloon pericardiotomy. This is a single-use device.
AccessGUDID Info
- FDA Product Code: OZT
- FDA Product Code Name: Balloon aortic valvuloplasty
- GMDN Term Code: 17453
- GMDN Term Name: Cardiac valvuloplasty catheter
- GMDN Term Description: A sterile flexible tube with an inflatable balloon designed to perform plastic or restorative surgery on a cardiac valve, i.e., for the dilatation of atrioventricular, aortic, and pulmonary trunk valves. It is typically used for the percutaneous dilatation of commissural fusion in stenotic mitral valves and for annular, cuspal, and calcific nodular fractures, to improve cuspal mobility in adult calcific aortic stenosis, and for leaflet tearing in pulmonic valve stenosis. It may also be used for percutaneous balloon pericardiotomy. This is a single-use device.
Manufacturer
C.R. Bard (a part of BD - Becton, Dickinson and Company) was a global leader in the development and manufacturing of innovative medical technologies. Known for their high-quality products, Bard specialized in solutions for vascular access, urology, oncology, and surgical specialties. Their product portfolio included catheters, biopsy devices, implantable ports, and hernia repair systems, designed to enhance patient care and procedural efficiency. As part of BD, the legacy of C.R. Bard continues to drive advancements in healthcare, delivering trusted solutions that improve outcomes for patients and providers worldwide.
IN-DATE